PowerCharge Pro Series

Ward's PowerCharge Pro Series can be tailored to suit electric vehicle charging needs for any electric vehicle (EV) and sized fleet. The sleek design with its automotive grade powder coat finish provides long lasting resistance to chipping, scratching and fading, and is environmentally friendly.

Pedestal-mount stations provide the flexibility for charging station placement in your fleets log. Charge two EVs at once with dual charge ports without any loss of charge speed.

Wall-mount stations are the right fit for parking garages, or areas where space is limited. Wall mount PowerCharge stations also offer simpler and lower cost of  installation.

Multiple Configurations

  • P10 — 16 Amps charging power, 10 miles range per charge hour
  • P20 — 30 Amps charging power, 20 miles range per charge hour
  • P30 — 40 Amps charging power, 30 miles range per charge hour
  • Dual or single charge ports
  • Pedestal stand or Wall mounted
  • Retractable cable option

Options run from a fully automated system using a Ward CANceiver, HID badge, key fob, magnetic stripe card, data key, keypad entry, or combinations of each, based on your unique business needs.


  • Versatile configurations
  • Data collection and reporting on-line
  • Long lasting powder coat finish
  • Cable retraction option
  • Revenue grade energy meter

Product Sheet


Input Voltage 208/240 VAC
Input Current 16A, 30A, 40A
Input Power Connections Line1, Line2, Earth required service
panel breaker, 16A/20A, 30A/40A, 40A/50A (current/breaker)
Dual station requires two feeds
Electrical Output 16A, 30A, 40A available
Output Charging Power 3.3kW, 7.2 kW, 9.6kW
Output Voltage 208/240 VAC
Output Charging Connector SAE J1772, 18 ft Cable
Ground Fault Detection 20mA CCID with automatic retry at 15-minute intervals, totaling three tries
Plug-Out Detection Power terminated per SAE J1772 specifications
Power Measurement Revenue grade energy metering
Optional Networks TCP/IP CAT 5/6, Wi-Fi, Zigbee, Cellular
Operating Temperature -30°C to +55°C
Terminal Block Temperature Rating +100°C
Operating Humidity 90% RH, non-condensing
Enclosure NEMA 3R
Safety Compliance ETL Listed for US and Canada;
Complies with UL 2594, UL 2231-1,UL 2231-2 Surge Protection 6kV
at 3000 VAC
EMC Compliance FCC Part 15 Class A



Fuel Control Terminal
Key fob


Fuel View

See Solutions Overview for relational details.